Penn foster exam 00603000 wiring electrical components

Questions 1 to 20: Select the best answer to each question. 

1. If you measure 20 feet between an existing box and a new box location, you should cut a piece of cable with a length of approximately
A. 20 to 21 ft.
B. 25 to 26 ft.
C. 40 to 42 ft.
D. 48 to 55 ft.

2. When a device is removed from an outlet box, the _______ wire must be connected in such a way that maintains continuity.
A. neutral
B. grounding
C. hot
D. grounded neutral

3. To correctly saw a lath and plaster wall, point the teeth of the saw
A. away from you and cut on the pushing stroke.
B. away from you and cut on the pulling stroke.
C. toward you and cut on the pushing stroke.
D. toward you and cut on the pulling stroke.

4. The labor performed when you extend an existing electrical system is called
A. old work.
B. repair work.
C. troubleshooting.
D. faultfinding.

5. The basement in an existing building has concrete walls, a concrete floor, and a concrete ceiling. From this information, you know that receptacles, lamp fixtures, and switches
A. can’t be installed in this basement as there is no way to ground the circuit.
B. won’t require ground-circuit protection because concrete insulates the occupants from ground.
C. can be installed in the basement and circuit wiring enclosed in a surface raceway system.
D. can only be installed if they’re connected with armored cable.

6. Which of the following tests must be performed on a 
de-energized circuit?
A. Power test
B. Continuity test
C. Voltage test
D. Current test

7. Each outside receptacle must be protected by
A. a GFCI.
B. its own ground rod.
C. a single- or double-pole switch.
D. its own circuit.

8. A circuit consists of five unequal loads connected in parallel. To measure the resistance through one specific load, you must
A. remove power from the circuit and measure the load’s resistance in its installed location.
B. apply power to the circuit, disconnect the load from the circuit, and measure the load’s resistance.
C. apply power to the circuit, measure the overall circuit resistance, and divide this value by five.
D. remove power from the circuit, disconnect the load from the circuit, and measure the load’s resistance.

9. When new work is being performed, an outlet box must have a minimum depth of
A. 1 in.
B. 11/2 in.
C. 2 in.
D. 21/2 in.

10. When new outlets are being added to the first floor of a two-story house with an unfinished basement, the easiest route for running cable is usually
A. behind the wall.
B. behind the baseboard.
C. by way of the second floor.
D. by way of the basement.

11. When an aluminum conductor is installed on a screw terminal, the screw should be tightened to a torque of
A. 8 lb-in.
B. 12 lb-in.
C. 15 lb-in.
D. 20 lb-in.

12. A fixed electric space heater that draws a maximum current of _______ must be supplied by a cable with an ampacity of 
30 A.
A. 15 A
B. 24 A
C. 27 A
D. 30 A

13. If a fixed appliance has an automatically started motor and is supplied by an individual branch circuit, the protection recommended is equal to or less than
A. twice the appliance rated current.
B. 125 percent of the appliance rated current.
C. the appliance rated current.
D. the full service current.

14. Which of the following is a true statement about the planning stages of adding a receptacle to an existing electrical system?
A. You must ensure that the existing circuit breaker will have enough capacity to handle the expected load to be applied at the new receptacle.
B. It’s not acceptable to bring power from an existing box containing a light switch.
C. Only nongrounding-type receptacles can be added to an existing system.
D. It isn’t necessary to identify joist or stud locations prior to adding a new receptacle.

15. When installing cable behind a wall, it’s recommended to run the cable behind the baseboard rather than through the studs when the
A. fish tape can’t be utilized.
B. wall is plasterboard.
C. wall studs are less than 16 inches apart.
D. wall is plaster or lath.

16. A device box with supports is the best choice when installing a
A. device box mounted in an existing drywall-covered wall.
B. device box in a lath ceiling.
C. device box that’s to be attached to a bar hanger.
D. shallow device box in either new or existing walls.

17. A transformer that’s used with a doorbell has a fixed output of
A. 1 V.
B. 10 V.
C. 60 V.
D. 120 V.

18. A suitable disconnecting means for a fixed appliance is a
A. pigtail cord.
B. light switch that interrupts the hot wire.
C. circuit breaker.
D. two-pole switch that interrupts the common wire.

19. The most efficient way to troubleshoot a defective electrical circuit is to start by
A. replacing the components that you believe are faulty.
B. having the power company evaluate the entire system’s operating efficiency.
C. breaking down a multiple-circuit system into isolated circuits to be evaluated one at a time.
D. bypassing the system’s main disconnect to ensure continuous power.

20. After routing cable from an existing device box through a wall and pulling the cable into a new box, your next step is to
A. replace the existing receptacle with a higher-capacity device.
B. apply power to the circuit.
C. strip and connect the wires to the existing receptacle.
D. tighten the internal cable clamps in the new box.







Calculate Your Essay Price
(550 words)

Approximate price: $22

Calculate the price of your order

550 words
We'll send you the first draft for approval by September 11, 2018 at 10:52 AM
Total price:
$26
The price is based on these factors:
Academic level
Number of pages
Urgency
Basic features
  • Free title page and bibliography
  • Unlimited revisions
  • Plagiarism-free guarantee
  • Money-back guarantee
  • 24/7 support
On-demand options
  • Writer’s samples
  • Part-by-part delivery
  • Overnight delivery
  • Copies of used sources
  • Expert Proofreading
Paper format
  • 275 words per page
  • 12 pt Arial/Times New Roman
  • Double line spacing
  • Any citation style (APA, MLA, Chicago/Turabian, Harvard)

Our guarantees

Delivering a high-quality product at a reasonable price is not enough anymore.
That’s why we have developed 5 beneficial guarantees that will make your experience with our service enjoyable, easy, and safe.

Money-back guarantee

You have to be 100% sure of the quality of your product to give a money-back guarantee. This describes us perfectly. Make sure that this guarantee is totally transparent.

Read more

Zero-plagiarism guarantee

Each paper is composed from scratch, according to your instructions. It is then checked by our plagiarism-detection software. There is no gap where plagiarism could squeeze in.

Read more

Free-revision policy

Thanks to our free revisions, there is no way for you to be unsatisfied. We will work on your paper until you are completely happy with the result.

Read more

Privacy policy

Your email is safe, as we store it according to international data protection rules. Your bank details are secure, as we use only reliable payment systems.

Read more

Fair-cooperation guarantee

By sending us your money, you buy the service we provide. Check out our terms and conditions if you prefer business talks to be laid out in official language.

Read more

Order your essay today and save 10% with the coupon code: best10